Online Access: |
http://jurnalinstrumentasi.bsn.go.id/index.php/ji/article/view/171 http://jurnalinstrumentasi.bsn.go.id/index.php/ji/article/view/171/pdf_48 http://jurnalinstrumentasi.bsn.go.id/index.php/ji/article/downloadSuppFile/171/50 http://jurnalinstrumentasi.bsn.go.id/index.php/ji/article/downloadSuppFile/171/51 |
ctrlnum |
article-171 |
---|---|
fullrecord |
<?xml version="1.0"?>
<dc schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd"><title lang="en-US">TAC METHOD TO OVERCOME THE PRACTICAL DIFFICULTY IN THE CALIBRATION OF DWT WITH INSENSITIVE PISTON</title><creator>Ega, Adindra Vickar; Pusat Penelitian Metrologi - LIPI
Research Center for Metrology - LIPI</creator><creator>Samodro, Rudi Anggoro; Pusat Penelitian Metrologi - LIPI
Research Center for Metrology - LIPI</creator><subject lang="en-US">metrology; pressure metrology; measurement</subject><subject lang="en-US">CF method; TAC method; low accuracy DWT; sensitive; calibration .</subject><subject lang="en-US">pressure metrology</subject><description lang="en-US">The crossfloat (CF) method is well-known for its accurate and reliable results, however the difficulty on performing CF method arises when dealing with insensitive piston of calibrated DWT. In contrary, automatic transducer assisted crossfloat (TAC) method could be implemented since it does not affected by this condition as it advantages. The used of TAC method could avoid up to 0.008% relative error of effective area at zero pressure and at 20 °C (A0,20) and twice higher error distortion coefficient (b) in case of calibrating insensitive piston of DWT. In addition, the TAC method has another advantage that is save time with consistent result because it can be performed automatically. Once should be consider when using TAC method is the accuracy of pressure transducer. In this case study, the existing pressure transducer owned by RCM – LIPI, could be utilized to perform automatic TAC method in lower pressure range down to 2 MPa that below 10% of its maximum scale, to calibrate low accuracy DWT greater than 0.08%.</description><publisher lang="en-US">LIPI Press, Anggota IKAPI</publisher><contributor lang="en-US"/><date>2019-11-11</date><type>Journal:Article</type><type>Other:info:eu-repo/semantics/publishedVersion</type><type>Other:</type><type>Other:TAC method</type><type>File:application/pdf</type><identifier>http://jurnalinstrumentasi.bsn.go.id/index.php/ji/article/view/171</identifier><identifier>10.31153/instrumentasi.v43i1.171</identifier><source lang="en-US">Instrumentasi; Vol 43, No 1 (2019); 11-23</source><source lang="id-ID">Instrumentasi; Vol 43, No 1 (2019); 11-23</source><source>2460-1462</source><source>0125-9202</source><language>eng</language><relation>http://jurnalinstrumentasi.bsn.go.id/index.php/ji/article/view/171/pdf_48</relation><relation>http://jurnalinstrumentasi.bsn.go.id/index.php/ji/article/downloadSuppFile/171/50</relation><relation>http://jurnalinstrumentasi.bsn.go.id/index.php/ji/article/downloadSuppFile/171/51</relation><rights lang="en-US">Copyright (c) 2019 Instrumentasi</rights><rights lang="en-US">http://creativecommons.org/licenses/by-nc/4.0</rights><recordID>article-171</recordID></dc>
|
language |
eng |
format |
Journal:Article Journal Other:info:eu-repo/semantics/publishedVersion Other Other: Other:TAC method File:application/pdf File Journal:Journal |
author |
Ega, Adindra Vickar; Pusat Penelitian Metrologi - LIPI
Research Center for Metrology - LIPI Samodro, Rudi Anggoro; Pusat Penelitian Metrologi - LIPI Research Center for Metrology - LIPI |
title |
TAC METHOD TO OVERCOME THE PRACTICAL DIFFICULTY IN THE CALIBRATION OF DWT WITH INSENSITIVE PISTON |
publisher |
LIPI Press, Anggota IKAPI |
publishDate |
2019 |
topic |
metrology pressure metrology measurement CF method TAC method low accuracy DWT sensitive calibration |
url |
http://jurnalinstrumentasi.bsn.go.id/index.php/ji/article/view/171 http://jurnalinstrumentasi.bsn.go.id/index.php/ji/article/view/171/pdf_48 http://jurnalinstrumentasi.bsn.go.id/index.php/ji/article/downloadSuppFile/171/50 http://jurnalinstrumentasi.bsn.go.id/index.php/ji/article/downloadSuppFile/171/51 |
contents |
The crossfloat (CF) method is well-known for its accurate and reliable results, however the difficulty on performing CF method arises when dealing with insensitive piston of calibrated DWT. In contrary, automatic transducer assisted crossfloat (TAC) method could be implemented since it does not affected by this condition as it advantages. The used of TAC method could avoid up to 0.008% relative error of effective area at zero pressure and at 20 °C (A0,20) and twice higher error distortion coefficient (b) in case of calibrating insensitive piston of DWT. In addition, the TAC method has another advantage that is save time with consistent result because it can be performed automatically. Once should be consider when using TAC method is the accuracy of pressure transducer. In this case study, the existing pressure transducer owned by RCM – LIPI, could be utilized to perform automatic TAC method in lower pressure range down to 2 MPa that below 10% of its maximum scale, to calibrate low accuracy DWT greater than 0.08%. |
id |
IOS15518.article-171 |
institution |
Badan Standardisasi Nasional |
institution_id |
258 |
institution_type |
library:special library |
library |
Perpustakaan Badan Standardisasi Nasional |
library_id |
22 |
collection |
Jurnal Instrumentasi |
repository_id |
15518 |
subject_area |
Standardization/Standarisasi Instrumentation Conformity Assessment |
city |
JAKARTA PUSAT |
province |
DKI JAKARTA |
repoId |
IOS15518 |
first_indexed |
2021-07-13T02:11:13Z |
last_indexed |
2021-07-13T02:11:13Z |
recordtype |
dc |
_version_ |
1705133886631051264 |
score |
17.610468 |