Comparison of hemoglobin level measurement results using sodium lauryl sulphate with oshiro and mansoor procedure

Main Authors: Fadhilah, Wasiyah Khusna, Al Badri, Muhammad Hilal, Wahid, Aziz Ansori, Fadhila, Feldha
Format: Article info application/pdf eJournal
Bahasa: eng
Terbitan: Lighthouse Publishing , 2022
Subjects:
Online Access: https://lighthouse-pub.com/ajhas/article/view/4
https://lighthouse-pub.com/ajhas/article/view/4/7
ctrlnum article-4
fullrecord <?xml version="1.0"?> <dc schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd"><title lang="en-US">Comparison of hemoglobin level measurement results using sodium lauryl sulphate with oshiro and mansoor procedure</title><creator>Fadhilah, Wasiyah Khusna</creator><creator>Al Badri, Muhammad Hilal</creator><creator>Wahid, Aziz Ansori</creator><creator>Fadhila, Feldha</creator><subject lang="en-US">Hemoglobin</subject><subject lang="en-US">Cyanmethmoglobin</subject><subject lang="en-US">Sodium lauryl sulfate</subject><subject lang="en-US">Oshiro procedure</subject><subject lang="en-US">Mansoor procedure</subject><description lang="en-US">The method of measuring Hb levels recommended by ICSH uses the HiCN method. However, it has a high risk due to the toxicity of the reagent. Therefore, the determination of Hb has been developed using the SLS method. According to Oshiro and Mansoor, who both stated that there was no significant difference between SLS and HiCN, this method has two distinct procedures. This study aims to determine the comparison between the measurement results of hemoglobin levels using sodium lauryl sulfate with the Oshiro procedure and Mansoor.&#xA0;The research design used is analytical research. The data obtained from the results of measuring Hb levels with the Oshiro and Manshoor procedures was given to students of the Diploma IV Study Program of Medical Laboratory Technology, Rajawali Health Institute batch 2018, which collected 49 people.&#xA0;The sampling technique used was saturated sampling to reduce the error rate in the study. The results of the normality test of the data in this study showed n of the two procedures was 49 mean&#xB1;SD for the Oshiro procedure 13.09&#xB1;0.56 and p = 0.200. Meanwhile, the Mansoor procedure had a meanSD of 13.09&#xB1;0.57 and a p-value of 0.059. Because the probability of both being p &amp;gt; 0.05, the data is declared normally distributed. The results of the average difference test from the data of this study show the mean&#xB1;SD of the pairwise difference between the Oshiro and Mansoor procedures is 0.002&#xB1;0.059 and the p value = 0.811. If P &amp;gt; 0.05, then it is stated that there is no significant difference between the two groups. The conclusion of this study is that the result of measuring Hb levels using the SLS procedure is reliable. Oshiro and Mansoor conform to HiCN and there is no significant difference in the mean results.</description><publisher lang="en-US">Lighthouse Publishing</publisher><date>2022-02-21</date><type>Journal:Article</type><type>Other:info:eu-repo/semantics/publishedVersion</type><type>File:application/pdf</type><identifier>https://lighthouse-pub.com/ajhas/article/view/4</identifier><identifier>10.53402/ajhas.v1i1.4</identifier><source lang="en-US">Asian Journal of Health and Applied Sciences; Vol. 1 No. 1 (2022): Asian Journal of Health and Applied Sciences (AJHAS); 23-28</source><source>2829-8985</source><source>10.53402/ajhas.v1i1</source><language>eng</language><relation>https://lighthouse-pub.com/ajhas/article/view/4/7</relation><rights lang="en-US">Copyright (c) 2022 Wasiyah Khusna Fadhilah, Muhammad Hilal Al Badri, Aziz Ansori Wahid, Feldha Fadhila</rights><rights lang="en-US">https://creativecommons.org/licenses/by-nc-sa/4.0</rights><recordID>article-4</recordID></dc>
language eng
format Journal:Article
Journal
Other:info:eu-repo/semantics/publishedVersion
Other
File:application/pdf
File
Journal:eJournal
author Fadhilah, Wasiyah Khusna
Al Badri, Muhammad Hilal
Wahid, Aziz Ansori
Fadhila, Feldha
title Comparison of hemoglobin level measurement results using sodium lauryl sulphate with oshiro and mansoor procedure
publisher Lighthouse Publishing
publishDate 2022
topic Hemoglobin
Cyanmethmoglobin
Sodium lauryl sulfate
Oshiro procedure
Mansoor procedure
url https://lighthouse-pub.com/ajhas/article/view/4
https://lighthouse-pub.com/ajhas/article/view/4/7
contents The method of measuring Hb levels recommended by ICSH uses the HiCN method. However, it has a high risk due to the toxicity of the reagent. Therefore, the determination of Hb has been developed using the SLS method. According to Oshiro and Mansoor, who both stated that there was no significant difference between SLS and HiCN, this method has two distinct procedures. This study aims to determine the comparison between the measurement results of hemoglobin levels using sodium lauryl sulfate with the Oshiro procedure and Mansoor. The research design used is analytical research. The data obtained from the results of measuring Hb levels with the Oshiro and Manshoor procedures was given to students of the Diploma IV Study Program of Medical Laboratory Technology, Rajawali Health Institute batch 2018, which collected 49 people. The sampling technique used was saturated sampling to reduce the error rate in the study. The results of the normality test of the data in this study showed n of the two procedures was 49 mean±SD for the Oshiro procedure 13.09±0.56 and p = 0.200. Meanwhile, the Mansoor procedure had a meanSD of 13.09±0.57 and a p-value of 0.059. Because the probability of both being p &gt; 0.05, the data is declared normally distributed. The results of the average difference test from the data of this study show the mean±SD of the pairwise difference between the Oshiro and Mansoor procedures is 0.002±0.059 and the p value = 0.811. If P &gt; 0.05, then it is stated that there is no significant difference between the two groups. The conclusion of this study is that the result of measuring Hb levels using the SLS procedure is reliable. Oshiro and Mansoor conform to HiCN and there is no significant difference in the mean results.
id IOS17271.article-4
institution Lighthouse Publishing Company
affiliation hellis.onesearch.id
institution_id 7614
institution_type archive:archive
archive
library Asian Journal of Health and Applied Sciences
library_id 5554
collection Asian Journal of Health and Applied Sciences
repository_id 17271
subject_area Medicine and Health/Ilmu Kedokteran, Ilmu Pengobatan dan Ilmu Kesehatan
Miscellany of Technology and Applied Sciences/Aneka Ragam tentang Teknologi dan Ilmu Terapan
Nursing and Services of Medical Technicians and Assistants/Perawat dan Teknisi Asisten Layanan Medik
Obstetric, Midwifery/Obstetri, Ilmu Kandungan, Ilmu Kebidanan
city KOTA BANDAR LAMPUNG
province LAMPUNG
shared_to_ipusnas_str 1
repoId IOS17271
first_indexed 2022-07-08T01:03:11Z
last_indexed 2022-07-08T01:03:11Z
recordtype dc
_version_ 1737744490135814144
score 17.612137