Analisis gangguan hubung singkat pada sistem tenaga listrik PLTD RAHA = Analysis of short circuit disorders in the RAHA PLTD electric power system

Main Authors: Michael Bonardo Siswono Sibarani, author, Add author: I Made Ardita Y., supervisor, Add author: Faiz Husnayain, examiner, Add author: Fauzan Hanif Jufri, examiner
Format: Bachelors Thesis
Terbitan: , 2020
Subjects:
Online Access: http://lontar.ui.ac.id/detail?id=20504822
ctrlnum 20504822
fullrecord <?xml version="1.0"?> <dc schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd"><type>Thesis:Bachelors</type><title>Analisis gangguan hubung singkat pada sistem tenaga listrik PLTD RAHA = Analysis of short circuit disorders in the RAHA PLTD electric power system</title><creator>Michael Bonardo Siswono Sibarani, author</creator><creator>Add author: I Made Ardita Y., supervisor</creator><creator>Add author: Faiz Husnayain, examiner</creator><creator>Add author: Fauzan Hanif Jufri, examiner</creator><publisher/><date>2020</date><subject>Short circuits</subject><subject>Electric circuit-breakers</subject><description>&lt;b&gt;ABSTRAK&lt;/b&gt;&lt;br&gt; Sistem Pembangkit Listrik Tenaga Diesel (PLTD) Raha memiliki jaringan pemakaian sendiri 20 kV untuk melayani setiap beban yang ada dalam jangkauan jaringan. Adanya gangguan hubung singkat dalam sistem tenaga listrik dapat menimbulkan masalah seperti kerusakan peralatan sistem tenaga listrik dan timbulnya pemadaman listrik. Oleh sebab itu, dibutuhkan suatu studi analisis untuk mengetahui arus gangguan hubung singkat yang akan terjadi sekaligus mengurangi akibat timbulnya kerusakan pada sistem. Pengujian ini bertujuan untuk mengetahui dan melihat potensi dari arus gangguan hubung singkat terbesar dengan menggunakan bantuan software ETAP 12.6.0. Berdasarkan hasil pengujian yang telah dilakukan, diketahui bahwa jenis gangguan hubung singkat 3 phasa merupakan jenis gangguan terbesar dan untuk gangguan terkecil pada jenis gangguan hubung singkat line to ground pada bus generator. Semakin banyak beban yang beroperasi, semakin besar pula nilai impedansi urutan positif dan negatif serta nilai arus hubung singkat. Impedansi urutan nol tidak berpengaruh terhadap jumlah beban yang beroperasi, begitu pun dengan pengaturan circuit breaker maupun kabel pada sistem tenaga listrik yang memiliki pengaturan tidak sesuai menurut standar yang digunakan. &lt;hr&gt; &lt;b&gt;ABSTRACT&lt;/b&gt;&lt;br&gt; Raha Diesel Power Station (PLTD Raha) utilizes a 20 kV grid to supply every load within the network reach. The presence of faults such as short circuits within an electric energy system can lead to problems such as damage on the electric energy apparatus and power outages. An analytical study is needed to understand the short circuit fault current and to decrease the effects of the incoming system failure. This simulation aims to observe and understand the short circuit fault current potential using Electrical Transient Analyzer Program (ETAP 12.6.0). This study shows that the biggest disruption is caused by the 3 phasa current with and for the smallest disturbance in the type of line to ground short circuit on the bus generator. The bigger the operating load, the larger the value of positive and negative sequence impedance as well as the short circuit current. The zerosequence impedance does not affect the amount of operating load, this also applies to the cables on the electric energy system that are not set according to standards.</description><identifier>http://lontar.ui.ac.id/detail?id=20504822</identifier><recordID>20504822</recordID></dc>
format Thesis:Bachelors
Thesis
Thesis:Thesis
author Michael Bonardo Siswono Sibarani, author
Add author: I Made Ardita Y., supervisor
Add author: Faiz Husnayain, examiner
Add author: Fauzan Hanif Jufri, examiner
title Analisis gangguan hubung singkat pada sistem tenaga listrik PLTD RAHA = Analysis of short circuit disorders in the RAHA PLTD electric power system
publishDate 2020
topic Short circuits
Electric circuit-breakers
url http://lontar.ui.ac.id/detail?id=20504822
contents <b>ABSTRAK</b><br> Sistem Pembangkit Listrik Tenaga Diesel (PLTD) Raha memiliki jaringan pemakaian sendiri 20 kV untuk melayani setiap beban yang ada dalam jangkauan jaringan. Adanya gangguan hubung singkat dalam sistem tenaga listrik dapat menimbulkan masalah seperti kerusakan peralatan sistem tenaga listrik dan timbulnya pemadaman listrik. Oleh sebab itu, dibutuhkan suatu studi analisis untuk mengetahui arus gangguan hubung singkat yang akan terjadi sekaligus mengurangi akibat timbulnya kerusakan pada sistem. Pengujian ini bertujuan untuk mengetahui dan melihat potensi dari arus gangguan hubung singkat terbesar dengan menggunakan bantuan software ETAP 12.6.0. Berdasarkan hasil pengujian yang telah dilakukan, diketahui bahwa jenis gangguan hubung singkat 3 phasa merupakan jenis gangguan terbesar dan untuk gangguan terkecil pada jenis gangguan hubung singkat line to ground pada bus generator. Semakin banyak beban yang beroperasi, semakin besar pula nilai impedansi urutan positif dan negatif serta nilai arus hubung singkat. Impedansi urutan nol tidak berpengaruh terhadap jumlah beban yang beroperasi, begitu pun dengan pengaturan circuit breaker maupun kabel pada sistem tenaga listrik yang memiliki pengaturan tidak sesuai menurut standar yang digunakan. <hr> <b>ABSTRACT</b><br> Raha Diesel Power Station (PLTD Raha) utilizes a 20 kV grid to supply every load within the network reach. The presence of faults such as short circuits within an electric energy system can lead to problems such as damage on the electric energy apparatus and power outages. An analytical study is needed to understand the short circuit fault current and to decrease the effects of the incoming system failure. This simulation aims to observe and understand the short circuit fault current potential using Electrical Transient Analyzer Program (ETAP 12.6.0). This study shows that the biggest disruption is caused by the 3 phasa current with and for the smallest disturbance in the type of line to ground short circuit on the bus generator. The bigger the operating load, the larger the value of positive and negative sequence impedance as well as the short circuit current. The zerosequence impedance does not affect the amount of operating load, this also applies to the cables on the electric energy system that are not set according to standards.
id IOS18066.20504822
institution Universitas Indonesia
institution_id 51
institution_type library:university
library
library Perpustakaan Universitas Indonesia
library_id 492
collection contoh Repository Tesis (Open) Universitas Indonesia
repository_id 18066
city KOTA DEPOK
province JAWA BARAT
repoId IOS18066
first_indexed 2022-12-14T02:23:50Z
last_indexed 2022-12-14T02:23:50Z
recordtype dc
merged_child_boolean 1
_version_ 1752185708005556224
score 17.610468