Effect Analysis of Unbalanced Electric Load in Ship at Three Phase Synchronous Generator on Laboratory Scale

Main Authors: Yulisetiawan, Radhin Dzaky; Institut Teknologi Sepuluh Nopember, Koenhardono, Eddy S.; Institut Teknologi Sepuluh Nopember, Sarwito, Sardono; Institut Teknologi Sepuluh Nopember
Format: Article info application/pdf eJournal
Bahasa: eng
Terbitan: Lembaga Penelitian dan Pengabdian Kepada Masyarakat (LPPM), ITS , 2017
Subjects:
Online Access: http://ejurnal.its.ac.id/index.php/teknik/article/view/19417
http://ejurnal.its.ac.id/index.php/teknik/article/view/19417/3366
ctrlnum article-19417
fullrecord <?xml version="1.0"?> <dc schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd"><title lang="en-US">Effect Analysis of Unbalanced Electric Load in Ship at Three Phase Synchronous Generator on Laboratory Scale</title><creator>Yulisetiawan, Radhin Dzaky; Institut Teknologi Sepuluh Nopember</creator><creator>Koenhardono, Eddy S.; Institut Teknologi Sepuluh Nopember</creator><creator>Sarwito, Sardono; Institut Teknologi Sepuluh Nopember</creator><subject lang="en-US">Teknik Sistem Perkapalan</subject><subject lang="en-US">Generator; Phasor Diagram; Power Produced; Unbalanced Load; Vibration</subject><description lang="en-US">The generator is the main power supply of electricity in the ship. The generator can supply each ship&#x2019;s electricity consumer regarding the generator capacity and consumer requirement. Until now, some research been developed to increase the efficiency of the generator. Besides that, in the operation of generator, there are several problems that cause the generator works inefficient, which one is an unbalanced load on each phase in generator. This final project analyzed the effect of unbalanced load in three phase synchronous generator. In this research conducted a simulation of the operational of the generator on board ship with a laboratory experiment. This research includes the phasor diagram drawing, efficiency, as well as vibrations generated by the generator at several loading conditions. The research results were when the generator on 50% load of the generator capacity (240 Watt), and the loads are getting unbalanced, the power produced by the generator is increased 30%, and the neutral current value also increased by 50%, compared with balanced load condition. Besides that, the vibration value in each condition is tend to fluctuate. This is applied for another experiment. In accordance to the generator operation on ship is when the loads are getting unbalance, the fuel consumption also increase. This shows that there is dissipation use in fuel oil consumption&#xA0;</description><publisher lang="en-US">Lembaga Penelitian dan Pengabdian Kepada Masyarakat (LPPM), ITS</publisher><date>2017-01-08</date><type>Journal:Article</type><type>Other:info:eu-repo/semantics/publishedVersion</type><type>File:application/pdf</type><identifier>http://ejurnal.its.ac.id/index.php/teknik/article/view/19417</identifier><source lang="en-US">Jurnal Teknik ITS; Vol 5, No 2 (2016)</source><language>eng</language><relation>http://ejurnal.its.ac.id/index.php/teknik/article/view/19417/3366</relation><rights>Authors who publish with this journal agree to the following terms: Authors retain copyright and grant the journal right of first publication with the work simultaneously licensed under a Creative Commons Attribution License that allows others to share the work with an acknowledgement of the work's authorship and initial publication in this journal.Authors are able to enter into separate, additional contractual arrangements for the non-exclusive distribution of the journal's published version of the work (e.g., post it to an institutional repository or publish it in a book), with an acknowledgement of its initial publication in this journal.Authors are permitted and encouraged to post their work online (e.g., in institutional repositories or on their website) prior to and during the submission process, as it can lead to productive exchanges, as well as earlier and greater citation of published work (See The Effect of Open Access).</rights><recordID>article-19417</recordID></dc>
language eng
format Journal:Article
Journal
Other:info:eu-repo/semantics/publishedVersion
Other
File:application/pdf
File
Journal:eJournal
author Yulisetiawan, Radhin Dzaky; Institut Teknologi Sepuluh Nopember
Koenhardono, Eddy S.; Institut Teknologi Sepuluh Nopember
Sarwito, Sardono; Institut Teknologi Sepuluh Nopember
title Effect Analysis of Unbalanced Electric Load in Ship at Three Phase Synchronous Generator on Laboratory Scale
publisher Lembaga Penelitian dan Pengabdian Kepada Masyarakat (LPPM), ITS
publishDate 2017
topic Teknik Sistem Perkapalan
Generator
Phasor Diagram
Power Produced
Unbalanced Load
Vibration
url http://ejurnal.its.ac.id/index.php/teknik/article/view/19417
http://ejurnal.its.ac.id/index.php/teknik/article/view/19417/3366
contents The generator is the main power supply of electricity in the ship. The generator can supply each ship’s electricity consumer regarding the generator capacity and consumer requirement. Until now, some research been developed to increase the efficiency of the generator. Besides that, in the operation of generator, there are several problems that cause the generator works inefficient, which one is an unbalanced load on each phase in generator. This final project analyzed the effect of unbalanced load in three phase synchronous generator. In this research conducted a simulation of the operational of the generator on board ship with a laboratory experiment. This research includes the phasor diagram drawing, efficiency, as well as vibrations generated by the generator at several loading conditions. The research results were when the generator on 50% load of the generator capacity (240 Watt), and the loads are getting unbalanced, the power produced by the generator is increased 30%, and the neutral current value also increased by 50%, compared with balanced load condition. Besides that, the vibration value in each condition is tend to fluctuate. This is applied for another experiment. In accordance to the generator operation on ship is when the loads are getting unbalance, the fuel consumption also increase. This shows that there is dissipation use in fuel oil consumption
id IOS2038.article-19417
institution Institut Teknologi Sepuluh November
institution_id 196
institution_type library:university
library
library Perpustakaan Institut Teknologi Sepuluh November
library_id 104
collection Jurnal Teknik ITS
repository_id 2038
city KOTA SURABAYA
province JAWA TIMUR
repoId IOS2038
first_indexed 2017-02-25T13:48:53Z
last_indexed 2017-02-25T13:48:53Z
recordtype dc
_version_ 1685754218867064832
score 17.610285