fullrecord <?xml version="1.0"?> <dc schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd"><title lang="en-US">Design and Fabrication of Compact MEMS Electromagnetic Micro-Actuator with Planar Micro-Coil Based on PCB</title><creator>Pawinanto, Roer Eka; Universiti Kebangsaan Malaysia</creator><creator>Yunas, Jumril; Universiti Kebangsaan Malaysia</creator><creator>Majlis, Burhanuddin; Universiti Kebangsaan Malaysia</creator><creator>Hamzah, Azrul; Universiti Kebangsaan Malaysia</creator><subject lang="en-US">MEMS, electromagnetic micro-actuator, printed circuit board (PCB), Silicon membrane, planar micro-coil</subject><description lang="en-US">This paper reports a compact design of electromagnetically driven MEMS micro-actuator utilizing planar electromagnetic coil on PCB (Printed Circuit Board). The micro-actuator device consists of an NdFeB permanent magnet, thin silicon membrane and planar micro-coil which fabricated using simple standard MEMS techniques with additional bonding step. Two planar coils designs including planar parallel and spiral coil structure with various coil geometry are chosen for the study. Analysis of the device involves the investigation of electromagnetic and mechanical properties using finite element analysis (FEA), the measurement of the membrane deflection and functionality test. The measurement results show that the thin silicon membrane is able to deform as much as 12.87 &#xB5;m using planar spiral micro-coil. Reasonable match between simulation and measurement of about 82.5% has been revealed. The dynamic response test on actuator driven by parallel planar coil shows that silicon membrane effectively deformed in 40 s for an input electrical power of only 150 mW. It is also concluded that planar parallel coil is considered for the simple structure and easy fabrication of the actuator system. This study will provide important parameters for the development of compact and simple electromagnetic micro-actuator system for fluidic injection system in lab-on-chip.</description><publisher lang="en-US">Universitas Ahmad Dahlan</publisher><contributor lang="en-US"/><date>2016-09-01</date><type>Journal:Article</type><type>Other:info:eu-repo/semantics/publishedVersion</type><type>Other:</type><type>File:application/pdf</type><identifier>http://journal.uad.ac.id/index.php/TELKOMNIKA/article/view/3998</identifier><identifier>10.12928/telkomnika.v14i3.3998</identifier><source lang="en-US">TELKOMNIKA (Telecommunication Computing Electronics and Control); Vol 14, No 3: September 2016; 856-866</source><source>2302-9293</source><source>1693-6930</source><source>10.12928/telkomnika.v14i3</source><language>eng</language><relation>http://journal.uad.ac.id/index.php/TELKOMNIKA/article/view/3998/2720</relation><rights lang="0">Copyright (c) 2016 Universitas Ahmad Dahlan</rights><rights lang="0">http://uad.ac.id</rights><recordID>article-3998</recordID></dc>
language eng
format Journal:Article
Journal
Other:info:eu-repo/semantics/publishedVersion
Other
Other:
File:application/pdf
File
Journal:eJournal
author Pawinanto, Roer Eka; Universiti Kebangsaan Malaysia
Yunas, Jumril; Universiti Kebangsaan Malaysia
Majlis, Burhanuddin; Universiti Kebangsaan Malaysia
Hamzah, Azrul; Universiti Kebangsaan Malaysia
title Design and Fabrication of Compact MEMS Electromagnetic Micro-Actuator with Planar Micro-Coil Based on PCB
publisher Universitas Ahmad Dahlan
publishDate 2016
topic MEMS
electromagnetic micro-actuator
printed circuit board (PCB)
Silicon membrane
planar micro-coil
url http://journal.uad.ac.id/index.php/TELKOMNIKA/article/view/3998
http://journal.uad.ac.id/index.php/TELKOMNIKA/article/view/3998/2720
contents This paper reports a compact design of electromagnetically driven MEMS micro-actuator utilizing planar electromagnetic coil on PCB (Printed Circuit Board). The micro-actuator device consists of an NdFeB permanent magnet, thin silicon membrane and planar micro-coil which fabricated using simple standard MEMS techniques with additional bonding step. Two planar coils designs including planar parallel and spiral coil structure with various coil geometry are chosen for the study. Analysis of the device involves the investigation of electromagnetic and mechanical properties using finite element analysis (FEA), the measurement of the membrane deflection and functionality test. The measurement results show that the thin silicon membrane is able to deform as much as 12.87 μm using planar spiral micro-coil. Reasonable match between simulation and measurement of about 82.5% has been revealed. The dynamic response test on actuator driven by parallel planar coil shows that silicon membrane effectively deformed in 40 s for an input electrical power of only 150 mW. It is also concluded that planar parallel coil is considered for the simple structure and easy fabrication of the actuator system. This study will provide important parameters for the development of compact and simple electromagnetic micro-actuator system for fluidic injection system in lab-on-chip.
id IOS2608.article-3998
institution Universitas Ahmad Dahlan
institution_id 62
institution_type library:university
library
library Perpustakaan Universitas Ahmad Dahlan
library_id 467
collection TELKOMNIKA Telecommunication, Computing, Electronics and Control
repository_id 2608
subject_area Rekayasa
Program Komputer dan Teknologi Informasi
city KOTA YOGYAKARTA
province DAERAH ISTIMEWA YOGYAKARTA
repoId IOS2608
first_indexed 2016-09-21T23:39:04Z
last_indexed 2018-04-19T22:44:20Z
recordtype dc
merged_child_boolean 1
_version_ 1685801217764098048
score 17.60897