PERHITUNGAN KINERJA PERPINDAHAN PANAS LOW PRESSURE HEATER 5 DAN 6 UNIT 1 PADA BEBAN 350 MW PLTU 3 JAWA TIMUR TANJUNG AWAR – AWAR TUBAN ( HEAT TRANSFER PERFORMANCE CALCULATION OF LOW PRESSURE HEATER 5 AND 6 UNIT 1 ON 350 MW LOAD PLTU 3 JAWA TIMUR TANJUNG AWAR – AWAR TUBAN )

Main Authors: Anantanur, Devi, Mrihardjono, Juli
Format: Thesis NonPeerReviewed application/pdf
Terbitan: , 2015
Subjects:
Online Access: http://eprints.undip.ac.id/47327/1/Cover_dll.pdf
http://eprints.undip.ac.id/47327/2/BAB_I_.pdf
http://eprints.undip.ac.id/47327/3/BAB_II.pdf
http://eprints.undip.ac.id/47327/4/BAB_III.pdf
http://eprints.undip.ac.id/47327/5/BAB_IV.pdf
http://eprints.undip.ac.id/47327/6/BAB_V.pdf
http://eprints.undip.ac.id/47327/
ctrlnum 47327
fullrecord <?xml version="1.0"?> <dc schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd"><title>PERHITUNGAN KINERJA PERPINDAHAN PANAS LOW PRESSURE HEATER 5 DAN 6 UNIT 1 PADA BEBAN 350 MW PLTU 3 JAWA TIMUR TANJUNG AWAR &#x2013; AWAR TUBAN&#xD; ( HEAT TRANSFER PERFORMANCE CALCULATION OF LOW PRESSURE HEATER 5 AND 6 UNIT 1 ON 350 MW LOAD PLTU 3 JAWA TIMUR TANJUNG AWAR &#x2013; AWAR TUBAN )&#xD; </title><creator>Anantanur, Devi</creator><creator>Mrihardjono, Juli</creator><subject>TJ Mechanical engineering and machinery</subject><description>Alat penukar panasmerupakan suatu komponen yang sangat penting dalam suatu industri yang melibatkan proses transfer panas seperti pembangkit listrik. Di pembangkit listrik, ada banyak alat penukar panas yang dapat melakukan proses transfer panas. Salah satunya adalah unit Low Pressure Heater. Low Pressure Heater merupakan alat penukar panas bertipe Shell and Tube dengan susunan pipanya berupa Pipa U. PLTU 3 Jawa Timur Tanjung Awar-Awar yang terdiri dari 2 unit yang beroperasi memasang masing &#x2013; masing 4 unit Low Pressure Heater, yaitu Low Pressure Heater 7-8, Low Pressure Heater 6 dan Low Pressure Heater 5. Tujuan dari penulisan tugas akhir ini adalah untuk mengetahui kinerja dari Low Pressure Heater tersebut atau tepatnya pada Low Pressure Heater 5 dan 6. Dengan metode effectiveness &#x2013; NTU, akan diketahui seberapa besar efektivitas yang diberikan oleh Low Pressure Heater 5 dan 6 tersebut. Penulis membatasi analisa alat penukar panas ini ketika unit 1 PLTU 3 Jawa Timur Tanjung Awar-Awar beroperasi pada beban 350 MW. Dengan proses perhitungan metode effectiveness &#x2013; NTU tersebut, diperoleh bahwa nilai efektivitas rata - rata yang diberikan ketika unit operasi pada beban 350 MW adalah sekitar 0,83 sehingga performa Low Pressure Heater 5 dan 6 masih dalam kondisi yang baik untuk dioperasikan.&#xD; Kata Kunci : Shell and Tube, Alat Penukar Panas, Low Pressure Heater, Effectiveness, NTU&#xD; &#xD; Heat Exchanger is an important component in the field of industries which brought some heat trasnfer&#x2019;s processe like a power plant. In this industries, there are many heat exchangers which brought heat transfer process. One of them is Low Pressure Heater. Low Pressure Heater is a Shell and Tube heat exchanger with U-Pipe pipping structure inside the heater. PLTU 3 Jawa Timur Tanjung Awar-Awarwhich has 2 operational units set 4 units of Low Pressure Heater. There are Low Pressure Heater 7-8, Low Pressure Heater 6 and Low Pressure Heater 5 in each operational unit. The purpose of thesis is for knowing the performance of one of the low pressure heater, for exactly Low Pressure Heater 5 and 6. Using the Effectiveness &#x2013; NTU methode, the writer will know the number of effectiveness which givem by this low pressure heater. The writer also limit the performance analysis of Low Pressure Heater when unit 1 of PLTU 3 Jawa Timur Tanjung Awar-Awar operate on 350 MW load. After analyzing with the effectiveness &#x2013; NTU methode, it gives the average effectivity when the unit operate on 350 MW load is 0,83. Therefore, the Low Pressure Heater 5 and 6&#x2019;s performance is absolutely in a good condition&#xD; Keywords : Shell and Tube, Heat Exchanger, Low Pressure Heater, Effectiveness, NTU&#xD; </description><date>2015-08</date><type>Thesis:Thesis</type><type>PeerReview:NonPeerReviewed</type><type>File:application/pdf</type><identifier>http://eprints.undip.ac.id/47327/1/Cover_dll.pdf</identifier><type>File:application/pdf</type><identifier>http://eprints.undip.ac.id/47327/2/BAB_I_.pdf</identifier><type>File:application/pdf</type><identifier>http://eprints.undip.ac.id/47327/3/BAB_II.pdf</identifier><type>File:application/pdf</type><identifier>http://eprints.undip.ac.id/47327/4/BAB_III.pdf</identifier><type>File:application/pdf</type><identifier>http://eprints.undip.ac.id/47327/5/BAB_IV.pdf</identifier><type>File:application/pdf</type><identifier>http://eprints.undip.ac.id/47327/6/BAB_V.pdf</identifier><identifier>Anantanur, Devi and Mrihardjono, Juli (2015) PERHITUNGAN KINERJA PERPINDAHAN PANAS LOW PRESSURE HEATER 5 DAN 6 UNIT 1 PADA BEBAN 350 MW PLTU 3 JAWA TIMUR TANJUNG AWAR &#x2013; AWAR TUBAN ( HEAT TRANSFER PERFORMANCE CALCULATION OF LOW PRESSURE HEATER 5 AND 6 UNIT 1 ON 350 MW LOAD PLTU 3 JAWA TIMUR TANJUNG AWAR &#x2013; AWAR TUBAN ). Undergraduate thesis, D3 Kerjasama PT. PLN bidang Teknik Mesin.</identifier><relation>http://eprints.undip.ac.id/47327/</relation><recordID>47327</recordID></dc>
format Thesis:Thesis
Thesis
PeerReview:NonPeerReviewed
PeerReview
File:application/pdf
File
author Anantanur, Devi
Mrihardjono, Juli
title PERHITUNGAN KINERJA PERPINDAHAN PANAS LOW PRESSURE HEATER 5 DAN 6 UNIT 1 PADA BEBAN 350 MW PLTU 3 JAWA TIMUR TANJUNG AWAR – AWAR TUBAN ( HEAT TRANSFER PERFORMANCE CALCULATION OF LOW PRESSURE HEATER 5 AND 6 UNIT 1 ON 350 MW LOAD PLTU 3 JAWA TIMUR TANJUNG AWAR – AWAR TUBAN )
publishDate 2015
topic TJ Mechanical engineering and machinery
url http://eprints.undip.ac.id/47327/1/Cover_dll.pdf
http://eprints.undip.ac.id/47327/2/BAB_I_.pdf
http://eprints.undip.ac.id/47327/3/BAB_II.pdf
http://eprints.undip.ac.id/47327/4/BAB_III.pdf
http://eprints.undip.ac.id/47327/5/BAB_IV.pdf
http://eprints.undip.ac.id/47327/6/BAB_V.pdf
http://eprints.undip.ac.id/47327/
contents Alat penukar panasmerupakan suatu komponen yang sangat penting dalam suatu industri yang melibatkan proses transfer panas seperti pembangkit listrik. Di pembangkit listrik, ada banyak alat penukar panas yang dapat melakukan proses transfer panas. Salah satunya adalah unit Low Pressure Heater. Low Pressure Heater merupakan alat penukar panas bertipe Shell and Tube dengan susunan pipanya berupa Pipa U. PLTU 3 Jawa Timur Tanjung Awar-Awar yang terdiri dari 2 unit yang beroperasi memasang masing – masing 4 unit Low Pressure Heater, yaitu Low Pressure Heater 7-8, Low Pressure Heater 6 dan Low Pressure Heater 5. Tujuan dari penulisan tugas akhir ini adalah untuk mengetahui kinerja dari Low Pressure Heater tersebut atau tepatnya pada Low Pressure Heater 5 dan 6. Dengan metode effectiveness – NTU, akan diketahui seberapa besar efektivitas yang diberikan oleh Low Pressure Heater 5 dan 6 tersebut. Penulis membatasi analisa alat penukar panas ini ketika unit 1 PLTU 3 Jawa Timur Tanjung Awar-Awar beroperasi pada beban 350 MW. Dengan proses perhitungan metode effectiveness – NTU tersebut, diperoleh bahwa nilai efektivitas rata - rata yang diberikan ketika unit operasi pada beban 350 MW adalah sekitar 0,83 sehingga performa Low Pressure Heater 5 dan 6 masih dalam kondisi yang baik untuk dioperasikan. Kata Kunci : Shell and Tube, Alat Penukar Panas, Low Pressure Heater, Effectiveness, NTU Heat Exchanger is an important component in the field of industries which brought some heat trasnfer’s processe like a power plant. In this industries, there are many heat exchangers which brought heat transfer process. One of them is Low Pressure Heater. Low Pressure Heater is a Shell and Tube heat exchanger with U-Pipe pipping structure inside the heater. PLTU 3 Jawa Timur Tanjung Awar-Awarwhich has 2 operational units set 4 units of Low Pressure Heater. There are Low Pressure Heater 7-8, Low Pressure Heater 6 and Low Pressure Heater 5 in each operational unit. The purpose of thesis is for knowing the performance of one of the low pressure heater, for exactly Low Pressure Heater 5 and 6. Using the Effectiveness – NTU methode, the writer will know the number of effectiveness which givem by this low pressure heater. The writer also limit the performance analysis of Low Pressure Heater when unit 1 of PLTU 3 Jawa Timur Tanjung Awar-Awar operate on 350 MW load. After analyzing with the effectiveness – NTU methode, it gives the average effectivity when the unit operate on 350 MW load is 0,83. Therefore, the Low Pressure Heater 5 and 6’s performance is absolutely in a good condition Keywords : Shell and Tube, Heat Exchanger, Low Pressure Heater, Effectiveness, NTU
id IOS2852.47327
institution Universitas Diponegoro
institution_id 69
institution_type library:university
library
library Perpustakaan Universitas Diponegoro
library_id 485
collection Diponegoro University Institutional Repository
repository_id 2852
city SEMARANG
province JAWA TENGAH
repoId IOS2852
first_indexed 2016-09-15T18:38:29Z
last_indexed 2016-09-22T21:23:40Z
recordtype dc
_version_ 1684483685779243008
score 17.610363