ANALYTICAL METHOD VALIDATION OF BENZENE USING HIGH PERFORMANCE LIQUID CHROMATOGRAPHY IN BEVERAGE CONTAINING SODIUM BENZOATE AND ASCORBIC ACID

Main Authors: Perwitasari, Melania, Lukitaningsih, Endang, Martono, Sudibyo
Format: Article info application/pdf
Bahasa: eng
Terbitan: Sanata Dharma University , 2014
Online Access: http://e-journal.usd.ac.id/index.php/JFSK/article/view/67
http://e-journal.usd.ac.id/index.php/JFSK/article/view/67/55
ctrlnum article-67
fullrecord <?xml version="1.0"?> <dc schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd"><title lang="en-US">ANALYTICAL METHOD VALIDATION OF BENZENE USING HIGH PERFORMANCE LIQUID CHROMATOGRAPHY IN BEVERAGE CONTAINING SODIUM BENZOATE AND ASCORBIC ACID</title><creator>Perwitasari, Melania</creator><creator>Lukitaningsih, Endang</creator><creator>Martono, Sudibyo</creator><subject lang="en-US"/><description lang="en-US">Abstract: Several countries reported discovering benzene in beverages containing benzoic acid&#xA0;and ascorbic acid. Benzoic acid decarboxylation by ascorbic acid will form benzene. American&#xA0;Beverage Association (ABA) recommended the use of accelerated testing to test benzene in&#xA0;beverages. High Performance Liquid Chromatography (HPLC) is one of several methods to&#xA0;analyze benzene in a wide variety of samples, but there is no much information provided&#xA0;regarding the validation of analysis method of benzene. Therefore, developing analysis method&#xA0;of benzene and its validation becomes a current need. The HPLC system consists of Hitachi L-2130 pump, sample injector with 20 &#xB5;L sample loop, and UV detector L-2420 operating at 205&#xA0;nm. The analytical column is a LiChrosorb Phenomenex RP-18 (250 x 4 mm, 10 &#xB5;m, 100 &#x1FA;), the&#xA0;mobile phase is acetonitrile:aquabidest (60:40 v/v) and pumped at a flow rate of 0,8 mL/min.Benzene separated from the matrix and follows the validation requirements. The developed&#xA0;analytical method showed that resolution was 8.37, r = 0.995 with LOD and LOQ 6.52 ppb and&#xA0;19.75 ppb, with a precise of &#x2264;11% and recovery of 80-110%. Accelerated testing indicated that&#xA0;benzene levels increased with increasing of the temperature. Beverages containing 400 mg/mL of&#xA0;ascorbic acid and benzoic acid formed benzene which was detected as 699.38 ppb at 25 oC,&#xA0;799.61 ppb at 40 oC, and 808.94 ppb at 60 oC in 48 hours. In conclusion, the method was fully&#xA0;validated and can be utilized to analyze benzene in beverages with the accelerated testing at 60 oC in 48 hours, so that benefits the producers and consumers in the end.Keywords : benzene, HPLC, validation method, ascorbic acid, benzoic acid</description><publisher lang="en-US">Sanata Dharma University</publisher><contributor lang="en-US"/><date>2014-05-01</date><type>Journal:Article</type><type>Other:info:eu-repo/semantics/publishedVersion</type><type>Journal:Article</type><type>File:application/pdf</type><identifier>http://e-journal.usd.ac.id/index.php/JFSK/article/view/67</identifier><identifier>10.24071/jpsc.11167</identifier><source lang="en-US">Journal of Pharmaceutical Sciences and Community; Vol 11, No 1 (2014)</source><source>2527-7146</source><source>1693-5683</source><language>eng</language><relation>http://e-journal.usd.ac.id/index.php/JFSK/article/view/67/55</relation><rights lang="en-US">Copyright (c) 2014 Melania Perwitasari, Endang Lukitaningsih, Sudibyo Martono</rights><rights lang="en-US">http://creativecommons.org/licenses/by/4.0</rights><recordID>article-67</recordID></dc>
language eng
format Journal:Article
Journal
Other:info:eu-repo/semantics/publishedVersion
Other
File:application/pdf
File
author Perwitasari, Melania
Lukitaningsih, Endang
Martono, Sudibyo
title ANALYTICAL METHOD VALIDATION OF BENZENE USING HIGH PERFORMANCE LIQUID CHROMATOGRAPHY IN BEVERAGE CONTAINING SODIUM BENZOATE AND ASCORBIC ACID
publisher Sanata Dharma University
publishDate 2014
url http://e-journal.usd.ac.id/index.php/JFSK/article/view/67
http://e-journal.usd.ac.id/index.php/JFSK/article/view/67/55
contents Abstract: Several countries reported discovering benzene in beverages containing benzoic acid and ascorbic acid. Benzoic acid decarboxylation by ascorbic acid will form benzene. American Beverage Association (ABA) recommended the use of accelerated testing to test benzene in beverages. High Performance Liquid Chromatography (HPLC) is one of several methods to analyze benzene in a wide variety of samples, but there is no much information provided regarding the validation of analysis method of benzene. Therefore, developing analysis method of benzene and its validation becomes a current need. The HPLC system consists of Hitachi L-2130 pump, sample injector with 20 μL sample loop, and UV detector L-2420 operating at 205 nm. The analytical column is a LiChrosorb Phenomenex RP-18 (250 x 4 mm, 10 μm, 100 Ǻ), the mobile phase is acetonitrile:aquabidest (60:40 v/v) and pumped at a flow rate of 0,8 mL/min.Benzene separated from the matrix and follows the validation requirements. The developed analytical method showed that resolution was 8.37, r = 0.995 with LOD and LOQ 6.52 ppb and 19.75 ppb, with a precise of ≤11% and recovery of 80-110%. Accelerated testing indicated that benzene levels increased with increasing of the temperature. Beverages containing 400 mg/mL of ascorbic acid and benzoic acid formed benzene which was detected as 699.38 ppb at 25 oC, 799.61 ppb at 40 oC, and 808.94 ppb at 60 oC in 48 hours. In conclusion, the method was fully validated and can be utilized to analyze benzene in beverages with the accelerated testing at 60 oC in 48 hours, so that benefits the producers and consumers in the end.Keywords : benzene, HPLC, validation method, ascorbic acid, benzoic acid
id IOS4028.article-67
institution Universitas Sanata Dharma
institution_id 710
institution_type library:university
library
library Perpustakaan Universitas Sanata Dharma
library_id 737
collection Journal of Pharmaceutical Sciences and Community
repository_id 4028
subject_area Pharmaceutical Sciences
Clinical Pharmacy
Community Pharmacy
city KOTA YOGYAKARTA
province DAERAH ISTIMEWA YOGYAKARTA
shared_to_ipusnas_str 1
repoId IOS4028
first_indexed 2017-03-20T06:48:17Z
last_indexed 2017-07-11T05:28:34Z
recordtype dc
_version_ 1686080619868585984
score 17.610468