<dc schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd"><title>ANALISIS DOSIS KELUARAN RADIASI DENGAN SUMBER Cs-137 PADA PROSES KALIBRASI PENDOSIMETER</title><creator>S.Si, MUHIJRAH</creator><subject>pendosimeter, Cs-137, calibration</subject><description>The research has been the dose of radiation output by 137 Cs source in the calibration
process pendosimeter use at a distance 200cm. Metode 50 ??Sv, 100 ??Sv, 500 ??Sv, 1000
??Sv scale used in this study is to provide a dose variation by changing the length of the
radiation, the longer the radiation source 137 Cs fired the greater in accepted. The factor
radiation dose calibration pendosimeter obtained from standard dose divided doses
measured, generally staying within the permitted between 0,8 ??? FK ??? 1,20.</description><date>2016-05-27T06:31:00Z</date><date>2016-05-27T06:31:00Z</date><date>2016-05-27</date><type>Journal:Article</type><identifier>http://repository.unhas.ac.id/handle/123456789/18656</identifier><recordID>123456789-18656</recordID></dc>
|
format |
Journal:Article Journal |
author |
S.Si, MUHIJRAH |
title |
ANALISIS DOSIS KELUARAN RADIASI DENGAN SUMBER Cs-137 PADA PROSES KALIBRASI PENDOSIMETER |
publishDate |
2016 |
topic |
pendosimeter Cs-137 calibration |
url |
http://repository.unhas.ac.id/handle/123456789/18656 |
contents |
The research has been the dose of radiation output by 137 Cs source in the calibration
process pendosimeter use at a distance 200cm. Metode 50 ??Sv, 100 ??Sv, 500 ??Sv, 1000
??Sv scale used in this study is to provide a dose variation by changing the length of the
radiation, the longer the radiation source 137 Cs fired the greater in accepted. The factor
radiation dose calibration pendosimeter obtained from standard dose divided doses
measured, generally staying within the permitted between 0,8 ??? FK ??? 1,20. |
id |
IOS5831.123456789-18656 |
institution |
Universitas Hasanuddin |
institution_id |
29 |
institution_type |
library:university library |
library |
Perpustakaan Universitas Hasanuddin |
library_id |
491 |
collection |
Repositori Universitas Hasanuddin |
repository_id |
5831 |
city |
KOTA MAKASSAR |
province |
SULAWESI SELATAN |
shared_to_ipusnas_str |
1 |
repoId |
IOS5831 |
first_indexed |
2018-07-01T15:20:21Z |
last_indexed |
2018-07-01T15:20:21Z |
recordtype |
dc |
_version_ |
1686398025603219456 |
score |
17.610468 |