Analisis Tingkat Efisiensi Daya dan Biaya Penggunaan Lampu Neon Sistem Elektronik Terhadap Neon Sistem Trafo Berdasarkan Desain Eksperimen Faktorial

Main Authors: Mahayanti, Rr. Dhiasty, Suhardi, Bambang, Astuti, Rahmaniyah Dwi
Format: Article info application/pdf eJournal
Bahasa: eng
Terbitan: Universitas Sebelas Maret , 2007
Subjects:
Online Access: https://jurnal.uns.ac.id/performa/article/view/11132
https://jurnal.uns.ac.id/performa/article/view/11132/9964
ctrlnum article-11132
fullrecord <?xml version="1.0"?> <dc schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd"><title lang="en-US">Analisis Tingkat Efisiensi Daya dan Biaya Penggunaan Lampu Neon Sistem Elektronik Terhadap Neon Sistem Trafo Berdasarkan Desain Eksperimen Faktorial</title><creator>Mahayanti, Rr. Dhiasty</creator><creator>Suhardi, Bambang</creator><creator>Astuti, Rahmaniyah Dwi</creator><subject lang="en-US">tube lamp; energy efficiency; factorial experimental design; cost calculation</subject><description lang="en-US">New innovation of electrics technology is not basically easy to permeated by society, includingsaving energy lamp. In fact, theese topics is interesting for the researchers. Reducing of electrics consumption in usage of lamp almost 50% from total cost usage of electrics energy. This research aim to choose the best tube lamp by considering of energy efficiency and reduce expense of electrics. Measuring input energy and output energy is conducted to two lamp type taken as this research namely transformer system lamp (NST) and electronic system lamp(NSE).Measuring of input energy and output energy is conduted by two factors experimental design with one block (Factorial Experiment Randomized Block Design). Theese factors are tube type and ballast type, while energy size as block. Result of research is analysed by using analysis of variant (Anova). Calculation of usage expense is conducted by considering four category according to electrics basic tariff (TDL). Based on analysis of variant, it is known that tube type and factor interaction do not have an effect significantly to input energy and output energy. While for the efficiency of energy, only tube type factor which do not show influence significantly.Percentage differenciation average of input energy, output energy, and energy efficiency NSE each 49%, 63%, and 49% bigger than NST. NSE more beneficial than NST as technically and economically. Most economical NSE is 20 watt.</description><publisher lang="en-US">Universitas Sebelas Maret</publisher><contributor lang="en-US"/><date>2007-03-01</date><type>Journal:Article</type><type>Other:info:eu-repo/semantics/publishedVersion</type><type>Journal:Article</type><type>File:application/pdf</type><identifier>https://jurnal.uns.ac.id/performa/article/view/11132</identifier><identifier>10.20961/performa.3.1.11132</identifier><source lang="en-US">PERFORMA: Media Ilmiah Teknik Industri; Vol 3, No 1 (2004): PERFORMA Vol. 3 No 1, Maret 2004</source><source>2620-6412</source><source>1412-8624</source><language>eng</language><relation>https://jurnal.uns.ac.id/performa/article/view/11132/9964</relation><rights lang="en-US">Copyright (c) 2017 PERFORMA : Media Ilmiah Teknik Industri</rights><recordID>article-11132</recordID></dc>
language eng
format Journal:Article
Journal
Other:info:eu-repo/semantics/publishedVersion
Other
File:application/pdf
File
Journal:eJournal
author Mahayanti, Rr. Dhiasty
Suhardi, Bambang
Astuti, Rahmaniyah Dwi
title Analisis Tingkat Efisiensi Daya dan Biaya Penggunaan Lampu Neon Sistem Elektronik Terhadap Neon Sistem Trafo Berdasarkan Desain Eksperimen Faktorial
publisher Universitas Sebelas Maret
publishDate 2007
topic tube lamp
energy efficiency
factorial experimental design
cost calculation
url https://jurnal.uns.ac.id/performa/article/view/11132
https://jurnal.uns.ac.id/performa/article/view/11132/9964
contents New innovation of electrics technology is not basically easy to permeated by society, includingsaving energy lamp. In fact, theese topics is interesting for the researchers. Reducing of electrics consumption in usage of lamp almost 50% from total cost usage of electrics energy. This research aim to choose the best tube lamp by considering of energy efficiency and reduce expense of electrics. Measuring input energy and output energy is conducted to two lamp type taken as this research namely transformer system lamp (NST) and electronic system lamp(NSE).Measuring of input energy and output energy is conduted by two factors experimental design with one block (Factorial Experiment Randomized Block Design). Theese factors are tube type and ballast type, while energy size as block. Result of research is analysed by using analysis of variant (Anova). Calculation of usage expense is conducted by considering four category according to electrics basic tariff (TDL). Based on analysis of variant, it is known that tube type and factor interaction do not have an effect significantly to input energy and output energy. While for the efficiency of energy, only tube type factor which do not show influence significantly.Percentage differenciation average of input energy, output energy, and energy efficiency NSE each 49%, 63%, and 49% bigger than NST. NSE more beneficial than NST as technically and economically. Most economical NSE is 20 watt.
id IOS7733.article-11132
institution Universitas Sebelas Maret
institution_id 18
institution_type library:university
library
library Performa: Media Ilmiah Teknik Industri
library_id 2712
collection Performa: Media Ilmiah Teknik Industri
repository_id 7733
subject_area Industrial and Manufacturing Engineering
Operation Research and Management
Decision Sciences
city KOTA SURAKARTA
province JAWA TENGAH
repoId IOS7733
first_indexed 2019-07-19T07:56:08Z
last_indexed 2019-07-19T07:56:08Z
recordtype dc
_version_ 1686565513304473600
score 17.611225