Study of dust collection effectiveness in cyclonic-vortex action apparatus

Main Authors: Andrei Torsky, Alexander Volnenko, Leonid Plyatsuk, Larysa Hurets, Daulet Zhumadullayev, Аbay Abzhabparov
Format: Article Journal
Bahasa: eng
Terbitan: , 2021
Subjects:
Online Access: https://zenodo.org/record/4773905
ctrlnum 4773905
fullrecord <?xml version="1.0"?> <dc schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd"><creator>Andrei Torsky</creator><creator>Alexander Volnenko</creator><creator>Leonid Plyatsuk</creator><creator>Larysa Hurets</creator><creator>Daulet Zhumadullayev</creator><creator>&#x410;bay Abzhabparov</creator><date>2021-02-27</date><description>The object of research is the efficiency of dust collection of fine dust in an apparatus with an intense turbulent mode of phase interaction. One of the most problematic areas of the existing dust and gas cleaning equipment is the low efficiency of collecting fine dust. Effective cleaning of exhaust gases from dust involves the use of multi-stage cleaning systems, including wet and dry dust cleaning devices, which entails high capital and operating costs. These disadvantages are eliminated in the developed design of the cyclone-vortex dust collector with two contact zones. The device implements both dry and wet dust collection mechanisms, which allows for high efficiency of dust removal at high productivity. The conducted studies of the total and fractional efficiency of dust collection when changing the operating parameters of the developed device showed that the efficiency of collecting fine dust is 98&#x2013;99 %. The increase in the efficiency of dust collection in the dry stage of the device is due to an increase in centrifugal force. In the wet stage of contact, the efficiency reaches its maximum values due to the vortex crushing of the liquid in the nozzle zone of the apparatus. Studies of the fractional efficiency of the apparatus show that with an increase in the diameter of the captured particles, the efficiency of the dust collection process for dry and wet stages, as well as the overall efficiency, increases. With an increase in the density of irrigation, the overall efficiency of dust collection in the apparatus increases. It has been established that an increase in the efficiency of capturing highly dispersed particles occurs due to turbulent diffusion, the value of which is determined by the frequency of turbulent pulsations and the degree of entrainment of particles during the pulsating motion of packed bodies. To describe the results obtained, a centrifugal-inertial model for a dry contact stage and a turbulent-diffusion model of solid particle deposition for a wet contact stage are proposed, which make it possible to calculate the dust collection efficiency of the contact stages, as well as the overall efficiency of the cyclone-vortex apparatus. The results obtained show the prospects of using devices of this design at heat power plants and other industries.</description><identifier>https://zenodo.org/record/4773905</identifier><identifier>10.15587/2706-5448.2021.225328</identifier><identifier>oai:zenodo.org:4773905</identifier><language>eng</language><rights>info:eu-repo/semantics/openAccess</rights><rights>https://creativecommons.org/licenses/by/4.0/legalcode</rights><source>Technology audit and production reserves 1(3(57)) 21&#x2013;25</source><subject>dust and gas emissions</subject><subject>complex cleaning</subject><subject>centrifugal force</subject><subject>regular packing</subject><subject>vortex interaction</subject><subject>dust collection efficiency</subject><title>Study of dust collection effectiveness in cyclonic-vortex action apparatus</title><type>Journal:Article</type><type>Journal:Article</type><recordID>4773905</recordID></dc>
language eng
format Journal:Article
Journal
Journal:Journal
author Andrei Torsky
Alexander Volnenko
Leonid Plyatsuk
Larysa Hurets
Daulet Zhumadullayev
Аbay Abzhabparov
title Study of dust collection effectiveness in cyclonic-vortex action apparatus
publishDate 2021
topic dust and gas emissions
complex cleaning
centrifugal force
regular packing
vortex interaction
dust collection efficiency
url https://zenodo.org/record/4773905
contents The object of research is the efficiency of dust collection of fine dust in an apparatus with an intense turbulent mode of phase interaction. One of the most problematic areas of the existing dust and gas cleaning equipment is the low efficiency of collecting fine dust. Effective cleaning of exhaust gases from dust involves the use of multi-stage cleaning systems, including wet and dry dust cleaning devices, which entails high capital and operating costs. These disadvantages are eliminated in the developed design of the cyclone-vortex dust collector with two contact zones. The device implements both dry and wet dust collection mechanisms, which allows for high efficiency of dust removal at high productivity. The conducted studies of the total and fractional efficiency of dust collection when changing the operating parameters of the developed device showed that the efficiency of collecting fine dust is 98–99 %. The increase in the efficiency of dust collection in the dry stage of the device is due to an increase in centrifugal force. In the wet stage of contact, the efficiency reaches its maximum values due to the vortex crushing of the liquid in the nozzle zone of the apparatus. Studies of the fractional efficiency of the apparatus show that with an increase in the diameter of the captured particles, the efficiency of the dust collection process for dry and wet stages, as well as the overall efficiency, increases. With an increase in the density of irrigation, the overall efficiency of dust collection in the apparatus increases. It has been established that an increase in the efficiency of capturing highly dispersed particles occurs due to turbulent diffusion, the value of which is determined by the frequency of turbulent pulsations and the degree of entrainment of particles during the pulsating motion of packed bodies. To describe the results obtained, a centrifugal-inertial model for a dry contact stage and a turbulent-diffusion model of solid particle deposition for a wet contact stage are proposed, which make it possible to calculate the dust collection efficiency of the contact stages, as well as the overall efficiency of the cyclone-vortex apparatus. The results obtained show the prospects of using devices of this design at heat power plants and other industries.
id IOS16997.4773905
institution ZAIN Publications
institution_id 7213
institution_type library:special
library
library Cognizance Journal of Multidisciplinary Studies
library_id 5267
collection Cognizance Journal of Multidisciplinary Studies
repository_id 16997
subject_area Multidisciplinary
city Stockholm
province INTERNASIONAL
shared_to_ipusnas_str 1
repoId IOS16997
first_indexed 2022-06-06T03:22:58Z
last_indexed 2022-06-06T03:22:58Z
recordtype dc
_version_ 1734898323392823296
score 17.60897